		<title>Cable Insulation during a Phase to Ground Fault</title>
		<description><![CDATA[I am designing a 480V HRG system consisting of 480V switchgear to a 480V MCC.  All my loads are three phase and I am beginning to specify equipment and cable.  I know I will have 173% on my unfaulted phases from a line to ground fault.  Should I be specifying insulation higher [...]]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/06/17/cable-insulation-during-a-phase-to-ground-fault/</link>
	</item>
<!-- next line added by Lev -->
<!-- next 2 lines added by Lev -->

	<item>
		<title>Transformer HRG Resistor Values</title>
		<description><![CDATA[What size Resistor should be specified for a 2500KVA Transformer with a 480V WYE connected secondary?  What happens if the value is smaller or larger than the "correct" value?  What happens if you have two paralled 2500KVA Transformers each with a HRG?  Should the HRG Value be adjusted then transformers are paralleled? ]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/05/21/transformer-hrg-resistor-values/</link>
	</item>
<!-- next line added by Lev -->
<!-- next 2 lines added by Lev -->

	<item>
		<title>IEEE &#038; NFPA formulas</title>
		<description><![CDATA[The problem is though, IEEE and NFPA formulas are based on 3-phase bolted faults. HRG doesn't even factor into the equation! Until they rewrite the formulas, there's not much we can mathematically do. ]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/05/08/ieee-nfpa-formulas/</link>
	</item>
<!-- next line added by Lev -->
<!-- next 2 lines added by Lev -->

	<item>
		<title>Existing installation</title>
		<description><![CDATA[What about existing installations? is just installing HRG that we solve possible risks? What else we should consider in a industrial installation? ]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/05/06/existing-installation/</link>
	</item>
<!-- next line added by Lev -->
<!-- next 2 lines added by Lev -->

	<item>
		<title>compare with GFCI</title>
		<description><![CDATA[On it's most basic level, is this the same principle as a GFCI outlet in a residential application? ]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/05/05/compare-with-gfci/</link>
	</item>
<!-- next line added by Lev -->
<!-- next 2 lines added by Lev -->

	<item>
		<title>Arcing faults</title>
		<description><![CDATA[I would say that use of HRG will greatly reduce the risk of arcing faults on a 480 V system, since the large majority of faults begin life as a line-to-ground fault. But what the others are saying is that it does NOT reduce the hazard that can exist for a three-phase arcing fault, so [...]]]></description>
		<link>http://expert.ecmweb.com/hrg-and-arc-flash/2008/05/01/arcing-faults/</link>